Catering to a wide clientele, our firm is proficient in manufacturing and exporting AHU. This air handling unit that we are providing is Composed with filter racks, dampers and sound attenuators. This unit is also provided with a spacious metal box which contains a blower that is efficient in  heating and cooling of elements. Our handling unit is applicable in various , hospitals, hotels and research labs. While we manufacture this AHU, we make sure that it is quality approved at every single step and finally aligned for the dispatch with safety measures.

Features:

  • Robust construction
  • Injected PUF insulation
  • Reliable operation

Air Handling Unit


We offer a wide array of Air Handling Units that are used in hotels, hospitals, research labs, multiplex malls and others. This system is used to condition and circulate air as part of a heating, ventilating and air-conditioning (HVAC) system. Comprised of filter racks or chambers, sound attenuators and dampers, it comes with a large metal box containing a blower that helps in heating and cooling elements.

Clean Room System


Chemietron has vast expertise in the designing of the HVAC systems for various Cleanroom applications.  We guarantee that our designed and installed systems meet the required Clean Room classification as well as the current international GMP standards - including those of EU and USA.  The central devices used are of the highest quality with low running costs and have low maintenance requirements. Energy conservation is always an important part of our design.  The AHUs used are specially made for the intended application and are very robust in construction giving our clients reliable operation throughout the project life.

HVAC Units

Chemietron has vast expertise in the designing of the HVAC systems for various Cleanroom applications.  We guarantee that our designed and installed systems meet the required Clean Room classification as well as the current international GMP standards - including those of EU and USA.  The central devices used are of the highest quality with low running costs and have low maintenance requirements. Energy conservation is always an important part of our design.  The AHUs used are specially made for the intended application and are very robust in construction giving our clients reliable operation throughout the project life.

Selection Parameter : -

  • Type  Floor Mount / Wall Mount / Horizontal / Vertical
  • Design  Blow Through / Draw Through
  • Frame Work :Thermal Break / Non Thermal Break
  • Panel MOC : Double Skinned / Singled Skinned
  • Base Frame : GI Skid with Corner / ‘C’ Channel
  • Outer Sheet : Pre-Coated with PC / Powder Coated
  • Inner Sheet :   Plain GI / Pre-Coated / SS
  • Panel Thick :    25mm / 45mm
  • Insulation :       Injected PUF @ 40±5 Kg/m3
  • Static Pressure :    50mm to 200mm WG
  • Types of Drive :     Belt Driven / Plug Fan
  • Types of Fan :        Backward Curved / Forward Curved
  • Filtration Stage     Pre-Filter / Fine Filter / Bag Filter / HEPA Filter
  • Filter Condition     Differential Pressure Port
  • Nos. of Damper    SA / RA / FA / PA
  • Type of Damper    Aerofoil / GI Powder Coated
  • Types of Zone       Inlet Lower with bird Screen

Return Air Plenum with RA / FA Damper

Pre-Filter Section / Bab Filter Section

HW / Steam / Heater Section

CHW / DX Coil Section

Mist Eliminator

Fan Section

Fine Filter Section